identiFINDER R500 Radionuclide Identification Detector

The FLIR identiFINDER R500 is the most sensitive radionuclide identification device (RID) available and is capable of rapidly locating and identifying radioactive material in dificult monitoring scenarios. Like other identiFINDER R-series products, the R500 contains on-board Bluetooth, web server, and GPS technologies. It produces rapid alerts that expedite response measures and enable field operators to make a next step determination.

The common operating interface and template matching technology provides immediate comfort and confi dence when using the device. The additional detector volume allows the R500 to identify radioactive material where other instruments cannot. When large areas need to be screened rapidly or there is potential for shielding, as in truck and cargo scanning, the identiFINDER R500 provides superior sensitivity and performance compared to other RID devices.

Features:

  • Large NaI or LaBr detector surface areas allow for detection of shielded sources and wide area scanning
  • Detects radiation source within a few seconds and reduces time to locate source
  • Available in gamma only or gamma and neutron models
  • High resolution, low false alarms
  • Fast, two-minute startup
  • Identifi es ANSI N42.34 library
  • Back-up gamma detector provides detection capability, even in high dose rate environments
  • Automatic calibration and continuous LED stabilization for temperature control and other conditional changes
  • Easily transfer important tactical information
  • On-board GPS, webserver, and Bluetooth capabilities
  • Common operating interface reduces training burden
  • Large, easy-to-read color display

identiFINDER R500 Radionuclide Identification Detector

SYSTEM OVERVIEW
Data Storage 2GB internal memory; up to 600,000 spectra
Training Requirements <10 mins for operator; 1 day for advanced user
ENVIRONMENTAL
Operating Humidity 10 to 80%
Operating Temperature -4 to 122 °F(-20 to 50 °C)
Storage Temperature 14 to 95 °F(-10 to 35 °C)
PHYSICAL FEATURES
Dimensions (L x W x H) 8.3 x 5.1 x 12.7 in (21.1 x 12.9 x 32.3 cm) - with battery
Weight ≤6.4 lbs(≤2.9 kg)
POWER
Battery Specs FLIR powerPACK ultra 2 (LSD NiMH, rechargeable); ≥8h operational batterylife; recharge ≤4h when using AC; recharge >4h when using USB
Cold Start Time <2 mins from cold start
Input Voltage 100-240 VAC (wall and car adapters and USB cable supplied)
SAMPLING & ANALYSIS
Nuclide Identification According to ANSI N42.34
Sample Introduction Absorption of EM gamma or neutron emissions
Threats Detects neutron or gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
SYSTEM INTERFACE
Communication USB 2.0; mini-B socket; Bluetooth® Class 2.0, ≤10m range
Software On-board webserver software
TECHNOLOGY
Corrections Real-time linearization of gamma spectrum
Dose Range 0 µSv- 1 Sv(0 µrem- 100 rem)
Dose Rate & Accuracy (Cs-137) 0.000 nSv/h – 1.00mSv/h (0 nrem/h – 100mrem/h)/ ±30 %
Energy Range [Gamma] 20 keV – 3 MeV
Gamma [High Dose Rate] Geiger-Mller
Gamma (NaI) 4.0 x 0.7 in (102 x 19mm
Gamma Spectrum 1024 channels; 3 MeV
Geiger-Muller Dose Rate Range 10 µSv/h - 1.0mSv/h (1.0mrem/h - 100mrem/h)
Overload Dose Rate Range 1mSv/h - 10mSv/h (100mrem/h - 1.0 rem/h)
Scintillator Dose Rate Range 0 nSv/h - 50 µSv/h (0 nrem/h - 5.0 mrem/h)
Service Interval 5 year factory maintenance
Stabilization Calibration source; LED
Technology Radioisotope identification device (RIID)
Typical Resolution ≤8 % FWHM; Variants

identiFINDER R500 Radionuclide Identification Detector

R500-NG Features a large diameter NaI(Tl) detector, GM detector and automatic calibration verification and peak stabilization. Features a color display, web server, Bluetooth, USB connectivity, and Reachback capability. Standard unit. Request technical specification document for complete specifications.
R500-NGH Features a large diameter NaI(Tl) detector, GM detector and automatic calibration verification and peak stabilization. Features a color display, web server, Bluetooth, USB connectivity, and Reachback capability. Standard unit containing a He3 tube for neutron detection. Request technical specification document for complete specifications.
R500-LG Features a 1.5" x 1.5" LaBr detector, GM detector and automatic calibration verification and peak stabilization. Features a TFT color display, web server, Bluetooth and micro USB cable communication. Standard unit. Request technical specification document for complete specifications.
R500-LGH Features a 1.5" x 1.5" LaBr detector, GM detector and automatic calibration verification and peak stabilization. Features a TFT color display, web server, Bluetooth and micro USB cable communication. Standard unit containing a He3 tube for neutron detection. Request technical specification document for complete specifications.

identiFINDER R500 Radionuclide Identification Detector

There are no reviews yet.


Related Items
Pen Radiation Dosimeter from S.E. International
Pen Radiation Dosimeter

S.E. International


$165.00
Radiation Alert Pen Dosimeter Charger from S.E. International

$290.00
Monitor 4EC from S.E. International
Monitor 4EC

S.E. International


$475.00
Radiation Alert Monitor 4 Monitor 4
Radiation Alert Monitor 4

S.E. International


$445.00