UOM: Box of 10

Item #: 154
MFG: GasTec
Sale: $89.14 Was: $94.17
$89.14

Cyclohexanone Detection Tubes (2 to 75 ppm)

Measures Cyclohexanone With a Range of 2-75 ppm. Other substances measurable with this detector tube are Furfural, Diacetone alcohol, and Isophorone (View these in table below).

  • Measuring Range: 2 to 30 ppm, 30 to 75 ppm
  • Number of Pump Strokes, 4, 2
  • Correction Factor: 1, 2.5
  • Sampling Time: 3 minutes per pump stroke
  • Detecting Limit: 0.2 ppm (n=4)
  • Changes from Pale Yellow to Yellow
  • Reaction Principle:
    • Cyclohexanone reacts with 2,4-dinitrophenylhydrazine to form dinitropnenylhydrazone to produce yellow in colour.
  • Coefficient of Variation: 10% (for 2 to 10 ppm), 5% (for 10 to 30 ppm)
  • 2 Year Shelf Life
  • TLV-TWA, C (ACGIH) (ppm): C 5
  • Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below.
  • Comes in a Box of 10

Instructions

Data Sheet

Other substance measurable with this detector tube:

Substance: Correction Factor: No. of Pump Strokes: Measuring Range:
Furfural 1.0 4 2 to 30 ppm
Diacetone alcohol by scale 2 2.5 to 100 ppm
Isophorone 1.0 8 2 to 30 ppm
Related Items
GasTec Detector Tube Pump GV-100-S-TR, GV-110-S-TR, GV-100-SOHA-TR, GV-110-SOHA-TR

Sale: $384.30
Hot Pack Tube Holder 8316130

Price: $275.00