ChromAir Chemical Exposure Monitoring Badges
The ChromAir chemical monitoring badge from Morphix Technologies is a direct-read autogenic exposimeter that measures dose exposure levels for specific toxic chemicals including Acetone, Ammonia, Carbon Monoxide, Chlorine, Formaldehyde, Glutaraldehyde, Mercury, Methyl Ethyl Ketone, Methyl Isobutyl Ketone, and Ozone. Since the badge is passive and relies on diffusion, it does not require a pump to operate. ChromAir badges give immediate, on-site results in the form of color-changing indicators that are effective, easy to read, and operable with minimal training.
Features:
- Immediate on-site results
- Easy-to-read color changing indicators
- Direct-read exposure data with immediate response times for short-term measurements
- Measures TWA exposure
- Patented design minimizes effects of humidity and velocity
- Light-weight and cost effective for personnel and area monitoring
ChromAir Chemical Exposure Monitoring Badges
Acetone
- Range: 20 - 24,000 ppm
- Min. Detectable Concentration: 2.5ppm
- Humidity Range: 15 - 95%
- Interferences: NH3, MEK, MIBK, MPK
- PN: 380020-10
Ammonia
- Range: 4 - 300 ppm
- Min. Detectable Concentration: 0.5 ppm
- Humidity Range: 15 - 90%
- Interferences: RNH2
- PN: 380003-10
Carbon Monoxide
- Range: 10 - 525 ppm
- Min. Detectable Concentration: 1.25 ppm
- Humidity Range: 19 - 85%
- Interferences: Alkenes, H2, H2S
- PN: 38008-10
Chlorine
- Range: 0.4 - 13 ppm
- Min. Detectable Concentration: 0.05 ppm
- Humidity Range: 35 - 85%
- Interferences: Br2, I2
- PN: 380004-10
Formaldehyde
- Range: 0.3 - 12 ppm
- Min. Detectable Concentration: 0.04 ppm
- Humidity Range: 30 - 80%
- Interferences: None Known
- PN: 380007-10
Glutaraldehyde
- Range: STEL (15 min)
- Min. Detectable Concentration: 0.04-0.95 ppm
- Humidity Range: 25 - 85%
- Interferences: None Known
- PN: 380017-10
Hydrogen Sulfide
- Range: 1 - 240 ppm
- Min. Detectable Concentration: 0.13 ppm
- Humidity Range: 33 - 80%
- Interferences: None Known
- PN: 380009-10
Mercury
- Range: 0.125 - 1.6 mg/m3 x hr
- Min. Detectable Concentration: 0.02 mg/m3
- Humidity Range: 10 - 80%
- Interferences: Strong Oxidizers
- PN: 380018-10
Methyl Ethyl Ketone
- Range: 18-21,600 ppm
- Min. Detectable Concentration: 2.25 ppm
- Humidity Range: 15 - 95%
- Interferences: NH3, acetone, MIBK, MPK
- PN: 380020-10
Methyl Isobutyl Ketone
- Range: 16 - 19,200 ppm
- Min. Detectable Concentration: 2.0 ppm
- Humidity Range: 15 - 95%
- Interferences: NH3, MEK, Acetone, MPK
- PN: 380020-10
Ozone
- Range: 0.08 - 1.6 ppm
- Min. Detectable Concentration: 0.01 ppm
- Humidity Range: 20 - 90%
- Interferences: H2O2, NO2
- PN: 380010-10
ChromAir Chemical Exposure Monitoring Badges
Chromair Chlorine Badge Exposure Example
ChromAir Chemical Exposure Monitoring Badges
There are no reviews yet.