Sensors:
|
Up to four field-replaceable sensors:
- LEL: Catalytic bead for combustibles (built-in Correction Factor library)
- Oxygen: Liquid electrolyte O2
- Toxic: electrochemical for H2S, CO, SO2, HCN
|
Battery
|
Rechargeable Lithium-ion
|
Run Time
|
14 hours continuous non-wireless, diffusion
11 hours continuous non- wireless, pumped
10 hours continuous with wireless, diffusion
8 hours continuous with wireless, pumped
|
Display
|
Monochrome graphic display (128x80)
Display Size: 1.57" x 1/06" with backlighting
Automatic or on-demand screen rotation
|
Keypad
|
Two button operation
|
Direct Readout
|
Real-time reading of gas concentrations
Battery status
Pump status (if equipped with pump
Wireless on/off and wireless reception quality
STEL, TWA, peak, and minimum values
Man Down and policy enforcement indicators
|
Alarm
|
Multi tone 95 dB buzzer, vibration alarm and flashing red LEDs and on-screen indication of alarm conditions
Alarms: Latching, non latching or manual override
Additional diagnostic alarm and display message for low battery
Pump stall alarm, pump version only
Man Down Alarm with pre-alarm and real time remote wireless notification
|
Datalogging
|
Continuous datalogging, 3 months for 4 sensors at 1 minute intervals
User configurable datalogging intervals, from1 to 3,600 seconds
|
Communication & Data Download
|
Data download and instrument set up and upgrades on PC via travel charger
Wireless data and status transmission via built in RF modem, optional
|
EMI/RFI
|
EMI & ESD Test: 100 MHz to 1 gHz 30V/m, no alarm
Contact: ±4kV
Air: ±8kV, no alarm
|
Wireless Network
|
Mesh Rae Systems Dedicated Wireless Network
ISM license free bands, 868MHz or 90MHz
|
Wireless Range
|
EchoView Host: LOS > 650 feet
Honeywell Safety Suite & Mesh Reader: LOS > 650 feet
Honeywell Safety Suite & RaeLink3: LOS > 330 feet
|
EM Immunity
|
EMI & ESD Test: 100MHz to 1GHz 30V/m, no alarm
Contact: ±4kV
Air: ±8kV, no alarm
|
IP Rating
|
Pumped: IP-65
Diffusion: IP-67
|
Calibration
|
Two point calibration for zero and span (manual or automatic with AutoRae 2)
|
Sampling Pump
|
Built in pump or diffusion
Can sample through tubing up to 98 feet
|
Temperature
|
-4 to 122°F
|
Humidity
|
0 to 95% rH, non condensing
|
Size
|
Diffusion: 5.5" L x 3.2" W x 1.5" H
Pumped: 5.7" L x 3.2" W x 1.7" H
|
Weight
|
Diffusion: 12.9 ounces
Pumped: 14.5 ounces
|
Approvals
|
US & Canada: Class I, Division 1, Groups A, B, C, D
|
Warranty
|
Unit: 2 years
O2, CO, H2S Sensors: 3 years
All Other Toxics: 1 year
|