Single Point Bump Test & Calibration Station for GX-2009

There are no reviews yet. | Write a review

Discontinued (Limited Stock May Be Available)

Item #: 81-SDM2009
Min Order: 0
Order Qty: Must order in multiples of 1
$1,224.68 Was: $1,290.00
Type:
Update price
View additional buying options
Product Details

Single Point Bump Test & Calibration Station for GX-2009

RKI’s SDM-2009 calibration station for the GX-2009 is available with advanced features for charging, calibration, & bump testing. Once you power up the GX-2009 inside the SDM-2009 calibration module, the GX-2009’s display will indicate whether it’s transmitting data, bump testing, calibrating, as well as the results of the bump test or calibration.

Multi Module System

The SDM-2009 can also be connected to a PC for automated calibration, bump testing, and archiving of logged data including calibration and bump test records, interval and alarm trends. Network up to 10 SDM-2009 stations to charge, calibrate, and bump test 10 instruments simultaneously.

Configurations:

P/N Contents
81-SDM2009-01 Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing & installation CD
81-SDM2009-02 Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator
81-SDM2009-03 Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 58AL cyl H2S (25 ppm)/CO/CH4/O2
81-SDM2009-06 Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 34AL cyl H2S (25 ppm)/CO/CH4/O2

Single Point Bump Test & Calibration Station for GX-2009

Input Power

12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard.

Environmental Conditions

  • For Indoor Use Only
  • -10° C to 40° C, below 80% Relative Humidity, Non-Condensing

Applicable Instruments

GX-2009

Max Records Saved

200 (stand-alone). Unlimited with software

Number of Cal Cylinders

1 Calibration gas, 1 fresh air and 1 exhaust

Standard Accessories

  • AC Adapter
  • USB Flash Drive
  • Single Module Data Viewer Software
  • SDM GX Docking Station PC Controller Program
  • Inlet Air Filter
  • Instruction Manual
  • 10 Foot Long Exhaust Tube
  • One 3 Foot Long Tube for GAS Fitting
  • 2 T-Fittings (for PC Controlled Configuration only)
  • 10 Foot Long 3/16 Inch Tube for GAS manifold-
    ing (used for PC Controlled Configuration only)
  • Check Valve (used for PC Controlled
    Configuration only)
  • USB Cable, Type A to Type B