Amines Detection Tubes (0.5 to 10 ppm)
Measures Amines
- Measuring Range of 0.5 to 10 ppm
- 1 Pump Stroke
- Sampling Time: 1 minute per pump stroke
- Detecting limit: 0.1 ppm (1 pump stroke)
- Detecting limit: 0.1 ppm (1 pump stroke)
- Changes from Pink to Yellow / Pale Orange
- Corrections for temperature & humidity: Temperature correction is necessary
- Relative Standard Deviation: 10% (for 0.5 to 2 ppm), 5% (for 2 to 10 ppm)
- 2 Year Shelf Life
- Reaction Principle: 2R?NH2 + H2SO4 ? (R?NH3)2SO4
- Store the tubes at a cool and dark place.
Amines measurable with this detector tube:
| Substance:
|
Correction Factor:
|
Measuring Range (ppm):
|
| Allylamine
|
0.8
|
0.4 to 8
|
| Butylamine
|
1.1
|
0.55 to 11
|
| Cyclohexylamine
|
1.0
|
0.5 to 10
|
| Di-n-butylamine
|
0.8
|
0.4 to 8
|
| Diethylamine
|
0.9
|
0.45 to 9
|
| Diethylaminoethanol
|
1.2
|
0.6 to 12
|
| Diethylenetriamine
|
1.9
|
0.95 to 19
|
| Diisopropylamine
|
0.6
|
0.3 to 6
|
| Dimethylamine
|
0.9
|
0.45 to 9
|
| 2-Dimethylaminoethanol
|
1.3
|
0.65 to 13
|
| Dimethylaminopropylamine
|
1.2
|
0.6 to 12
|
| N,N-Dimethylethylamine
|
0.6
|
0.3 to 6
|
| Dipropylamine
|
0.7
|
0.35 to 7
|
| Ethanolamine
|
3.9
|
1.95 to 39
|
| Ethylamine
|
0.9
|
0.45 to 9
|
| Ethylenediamine
|
1.8
|
0.9 to 18
|
| N-Ethylmorpholine
|
0.6
|
0.3 to 6
|
| Hexamethylenediamine
|
3.1
|
1.55 to 31
|
| Hexylamine
|
1.3
|
0.65 to 13
|
| Isopropylamine
|
0.9
|
0.45 to 9
|
| Methylamine
|
1.0
|
0.5 to 10
|
| Morpholine
|
1.0
|
0.5 to 10
|
| N-Methylmorpholine
|
0.6
|
0.3 to 6
|
| Pentamethylenediamine
|
1.5
|
0.75 to 15
|
| Propylamine
|
1.0
|
0.5 to 10
|
| Propyleneimine
|
0.7
|
0.35 to 7
|
| Tetramethylenediamine
|
1.6
|
0.8 to 16
|
| Triethylamine
|
0.6
|
0.3 to 6
|
| Trimethylamine
|
0.5
|
0.25 to 5
|
Amines Detection Tubes (0.5 to 10 ppm)
There are no reviews yet.