Hydrazine Detection Tubes 0.25/a (0.1 - 10 ppm)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces.
Hydrazine Detection Tubes 0.25/a (0.1 - 10 ppm)
| Standard Measuring Range: |
0.25 to 10 / 0.1 to 5 ppm |
| Number of Strokes (n): |
10 / 20 |
| Time for Measurement: |
approx. 1 min / approx. 2 min |
| Standard Deviation: |
±10 to 15 % |
| Color Change: |
yellow ?> blue |
| Temperature: |
10 to 50° C |
| Absolute Humidity: |
< 20 mg H2O / L |
| Reaction Principle: |
N2H4 + pH Indicator ??> blue reaction product |
| Cross Sensitivity: |
This tube indicates other basic gases (e.g. organic amines and ammonia), however, with differing sensitivity. |
Hydrazine Detection Tubes 0.25/a (0.1 - 10 ppm)
There are no reviews yet.
Draeger-Tube Accuro Pump or automatically with the
Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces.
">