Carbon Disulfide 0.63-100 ppm Detection Tubes
Gastec Detection Tube No. 13 measures Carbon Disulfide with a Range of 0.63 to 100 ppm.
- Measuring Range:
- 0.63 to 1.25 ppm
- 1.25 to 2.5 ppm
- (2.5) to 50 ppm
- 50 to 100 ppm
- No. of Pump Strokes: 4, 2, 1, 1/2
- Correction Factor: 1/4, 1/2, 1, 2
- Sampling Time: 12 min, 6 min, 3 min, 1.5 min
- Detecting Limit: 0.3 ppm (4 pump strokes)
- Color Change: Blue to Yellow
- Correction for Temperature & Humidity: Temperature correction is necessary
- Relative standard deviation: 10 % (for 2.5 to 10 ppm), 5 % (for 10 to 50 ppm)
- Shelf Life: 3 years
- Reaction Principle:
- CS2 + CrO3 + H2S2O7 ? SO2 + CO2
- SO2 + BaCl2 + H2O ? BaSO3 + 2HCl
- HCl + Base ? Chloride
Possible coexisting substances and their interferences:
| Substance |
Concentration |
Interference |
Changes color by itself to |
| Sulfur dioxide |
? 1/5 |
+ |
Yellow |
| Ammonia |
|
No |
No |
| Hydrogen cyanide |
? 200 ppm |
No |
No |
| Hydrogen sulfide is trapped in the pretreatment layer. |
Carbon Disulfide 0.63-100 ppm Detection Tubes
Reaction Principle:
CS2 + CrO3 + H2O7 to SO2 + CO2
SO2 + BaCl2 + H2O to BaSO3 + 2HCl
HCI + Base to Chloride
Possible coexisting substances and their interferences:
| Substance:
|
Concentration:
|
Interference:
|
Changes color by itself to:
|
| Sulphur Dioxide
|
? 1/5
|
?
|
Yellow
|
| Ammonia
|
|
No
|
No
|
| Hydrogen Cyanide
|
? 200 ppm
|
No
|
No
|
*Hydrogen Sulphide is trapped in pretreatment layer
Carbon Disulfide 0.63-100 ppm Detection Tubes
There are no reviews yet.