Item #: 6728111
MFG: Draeger
Price: $92.40
$92.40

Epichlorohydrin Detection Tubes 5/b (5 - 50 ppm)

For short-term measurements more than 160 Draeger-Tubes are available to measure the so-called spot concentrations of specific gases. A wide range of different gases and vapours can be detected and measured, e.g.: Determining and measuring concentration peaks, Measuring personal exposure in the inhalation area, Detecting leaks in pipelines, gas installations etc., and Air analysis in sewers, shafts and confined spaces.

Contains 10 tubes

Standard Measuring Range5 to 80 ppm
Number of Strokes (n)20
Time for Measurementapprox. 8 min.
Standard Deviation±15 to 20%
Colour Changepale gray ─> yellow orange
Temperature10 to 40° C
Absolute Humidity5 to 15 mg H2O / L
Reaction PrincipleEpichlorohydrin + Cr ^VI ─> Cl2

Cl2 + o-tolidine > yellow orange reaction
product
Cross SensitivityOther chlorinated hydrocarbons are indicated
as well but with different sensitivities. It is not
possible to measure epichlorohydrin in the
presence of free halogens and hydrogen
halides in the TLV range because they are
indicated as well. Petroleum hydrocarbons
cause low readings.
Related Items