General |
| Thermal Resolution: |
160 × 120 (19,200 pixels) |
| Battery Life: |
Approximately 2 hours 30 minutes |
| Object Temperature Range: |
-4°F — 248°F to 32°F — 752°F |
| Accuracy: |
±5.4°F or ±5%. Applicable 60 sec after start-up when the unit is within 59°F to 95°F and the scene is within 41°F to 248°F |
| Operating Temperature: |
14°F to 122°F, battery charging 32°F to 113°F |
| Spot Meter: |
Hottest, Coldest and 3 spot measurement |
| Battery charge monitor: |
0 — 100% |
| Clip Span: |
130 mm (min) / 195 mm (max) |
| Compatible with FLIR software: |
FLIR ONE app, FLIR Ignite, FLIR Thermal Studio |
| Device Compatibility: |
iOS (version 15 and later) or Android (version 11 and later) smartphones and tablets |
| Dimensions (H x W x D): |
1.5 in × 1.4 in × 5.9 in |
| Remote Operation: |
Up to 16.4 ft from smart device via Wi-Fi |
| Weight: |
5.4 oz |
Imaging & Optical |
| Adjustable MSX distance: |
30 cm — Infinity |
| Focus: |
Fixed 30 cm — Infinity |
| Frame Rate: |
8.7 Hz |
| HFOV/VFOV: |
54° ±1° / 42° ±1° |
| Image Modes: |
Infrared, visual, MSX |
| Palette: |
Gray (white hot), Hottest, Coldest, Iron, Contrast, Arctic, Lava and Color Wheel |
| Shutter: |
Automatic/Manual |
| Thermal Resolution: |
160 × 120 (19,200 pixels) |
| Thermal Sensitivity/NETD: |
70 mK |
| Thermal Sensor: |
Pixel size 12 µm, 8 — 14 µm spectral range |
| Visual Resolution: |
640 × 480 |
| VividIR: |
Yes |
Power |
| Battery charge time: |
60–90 min for fully charged 15 min charging, from empty battery, gives 40 min operating time
|
| Battery Life: |
Approximately 2 hours 30 minutes |
| Charging Method: |
Female USB-C (5V/1A) |
Measurement & Analysis |
| Accuracy: |
±5.4°F or ±5%. Applicable 60 sec after start-up when the unit is within 59°F to 95°F and the scene is within 41°F to 248°F |
| Measurement Corrections: |
Emissivity; Reflected apparent temperature (72°F) |
| Object Temperature Range: |
–4°F — 248°F and 32°F — 752°F |
| Spot Meter: |
Hottest, Coldest and 3 spot measurement |
Environmental & Certifications |
| Certifications: |
RoHS, CE/FCC, CEC-BC, EN62133, UL1642, WEEE 2012/19/EU, IP54 |
| Drop test: |
Drop from 6.56 ft |
| Emissivity Settings: |
Matte: 95%, Semi-Matte: 80%, Semi-Glossy: 60%, Glossy: 30% |
| Non-Operating Temperature: |
-40°F to 158°Ft |
| Operating Temperature: |
-14°F to 122°F, battery charging 32°F to 113°F |
Communication & Data Storage |
| Bluetooth: |
Uses Bluetooth to set up the peer-to-peer Wi-Fi network that the camera creates to connect to the mobile device |
| Drop test: |
Video, Still image |
| Charging: |
Female USB-C (5V/1A) |
| File Formats |
Radiometric JPG, MPEG-4 (file format MOV (iOS), MP4 (Android)) |
| WiFi |